| IP module/transmitter ET7 ET7 is a communicator designed to transmit intruder alarms to monitoring station over Internet networks. 
 Main features
 Is compatible with alarm control panels of Paradox, DSC, Pyronix and GE;Connected direct to the Common Bus or Serial Output;Transfers intruder alarms in form of Contact ID codes over IP networks;Directs the transmission to 2 IP addresses;USB port for on-site configuring and upgrading;For wider application external interfaces are using.
 Technical specifications Intruder alarms transmitting to CMS*: by either TCP/IP or UDP/IP protocol to 2 IP addresses over IP networksData output: Ethernet, IEEE 802.3, 10 Base-T, RJ45Data packet: In Contact ID codesMemory: 100 eventsPower supply: 12,6 V DC, 10-15 VCurrent:Standby - up to 120 mATransmitting mode - up to 250 mA
 Inputs: 2 of NC typeOutputs: 1 of OC type, 30V, 100 mAConfiguration jack: USBOperating temperature: -10 °C to +55 °CDimensions: 65 x 79 x 25 mmWeight: 0,1 kg
*CMS - Central Monitoring Station 
 
  C11 is an external interface for GSM module GT7, GT10 and IP module ET7, designed to receive data from telephonic communicator of a control panel. Input in DTMF signals and in Contact ID protocol. CZ6 is an external interface designed to increase the number of GSM module GT7, GT10 and IP module ET7 inputs up to 6. C14 is an external interface applied for interconnecting modules ET7, GT7 and GT10 with the output TIP-RING of control panel. Input in DTMF signals and in Contact ID protocol.
 |